Pre-COLREG 1972 Sound Practices

Before the introduction of COLREG 1972, smaller vessels often used low-pitched tones, which were typically reserved for larger ships. This practice was not as strict as required. However, modern IMO regulations ensure that very low tones are exclusively used by the largest vessels, while medium and smaller vessels have more flexibility in frequency selection. Vessel LOA 75m – 200m

Whistle Options for Vessel LOA 75m – 200m

Kockum Sonics offers whistles for vessels 75m to 200m in length overall. The MT150/130 is an electrically driven piston whistle with minimal moving parts, suitable for all temperature operations. The Supertyfon® AT150/130- 330 series is an air-driven whistle with a frequency range of 130Hz to 330Hz and comes with the TV784 Valve control unit.

Contact Us for More Information

If you have any questions or require spare parts for your  Kockum Sonics system.

contact us.
AT 150/130 Supertyfon
Kockum Sonics / Vessel LOA 75m - 200m / Whistles & Tyfons

AT 150/130 Supertyfon®

 
part no.

25800033

product options

AT 150/130 air whistle, suitable for vessels with a LOA 75m till 200m.

 

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

 

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels between 75 and 200 meters (246 – 656 feet) should use whistles with frequencies ranging between 130 and 350 Hz. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for AT 150/130

Mounting the AT 150/130

Secure the AT 150/130 whistle with four M16 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for ensuring optimal performance. To begin with, it is recommended to drain the filter approximately once a month. By doing so, you can effectively prevent blockages while also maintaining the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 130 Hz
  • Sound Pressure Level (1m):
    Total: 148 dB
    1/3 octave IMO limit: 138 dB
  • Air consumption: 35 – 45 I/s
  • Air supply pressure with choke regulation:
    0,6 – 3 MPa (6 – 30 bar)
  • Electric power:
    Thermostat heating: 24 W
    Valve: 27 W
  • Weight: 65 kg
  • For wiring diagram: see Valve Unit TV 784.
Kockum Sonics / Vessel LOA 75m - 200m / Whistles & Tyfons

AT 150/165 Supertyfon®

 
part no.

25800029

product options

AT 150/165 air whistle, suitable for vessels with a LOA 75m till 200m.

 

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

AT 150/165

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels between 75 and 200 meters (246 – 656 feet) should use whistles with frequencies ranging between 130 and 350 Hz. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for AT 150/165

Mounting the AT 150/165

Secure the AT 150/165 whistle with four M10 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for optimal performance. Drain the filter approximately once a month to prevent blockages and maintain the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 165 Hz
  • Sound Pressure Level (1m):
    Total: 148 dB
    1/3 octave IMO limit: 138 dB
  • Air consumption: 25 – 35 I/s
  • Air supply pressure with choke regulation:
    0,6 – 3 MPa (6 – 30 bar)
  • Electric power:
    Thermostat heating: 24 W
    Valve: 8-15 W
  • Weight: 14 kg
  • For wiring diagram: see Valve Unit TV 784.
AT 150/200
Kockum Sonics / Vessel LOA 75m - 200m / Whistles & Tyfons

AT 150/200 Supertyfon®

 
part no.

25800027

product options

AT 150/200 air whistle, suitable for vessels with a LOA 75m till 200m.

 

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

 

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels between 75 and 200 meters (246 – 656 feet) should use whistles with frequencies ranging between 130 and 350 Hz. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for AT 150/200

Mounting the AT 150/200

Secure the AT 150/200 whistle with four M10 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for optimal performance. Drain the filter approximately once a month to prevent blockages and maintain the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 200 Hz
  • Sound Pressure Level (1m):
    Total: 148 dB
    1/3 octave IMO limit: 138 dB
  • Air consumption: 20 – 30 I/s
  • Air supply pressure with choke regulation:
    0,6 – 3 MPa (6 – 30 bar)
  • Electric power:
    Thermostat heating: 24 W
    Valve: 27 W
  • Weight: 12,5 kg
  • For wiring diagram: see Valve Unit TV 784
AT 150/330
Kockum Sonics / Vessel LOA 75m - 200m / Whistles & Tyfons

AT 150/330 Supertyfon®

 
part no.

25800025

product options

AT 150/330 air whistle, suitable for vessels with a LOA 75m till 200m

 

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

 

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels between 75 and 200 meters (246 – 656 feet) should use whistles with frequencies ranging between 130 and 350 Hz. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for AT 150/330

Mounting the AT 150/330

Secure the AT 150/330 whistle with four M10 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for optimal performance. Drain the filter approximately once a month to prevent blockages and maintain the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 330 Hz
  • Sound Pressure Level (1m):
    Total: 148 dB
    1/3 octave IMO limit: 138 dB
  • Air consumption: 20 – 30 I/s
  • Air supply pressure with choke regulation:
    0,6 – 3 MPa (6 – 30 bar)
  • Electric power:
    Thermostat heating: 24 W
    Valve: 27 W
  • Weight: 11,5 kg
  • For wiring diagram: see Valve Unit TV 784
AT 150/330 zone 2
Kockum Sonics / Inland Shipping / Vessel LOA 20m - 75m / Vessel LOA 75m - 200m / Whistles & Tyfons

AT 150/330 Supertyfon® Inland Shipping

 
part no.

24801501

product options

AT 150/330 air whistle, designed to meet regulations Zone 2 German inland waterways.

 

Powerful IMO-Compliant Air Horn for Inland Waters

The AT150/330 is a powerful air horn designed to meet IMO maritime regulations for inland waterways, including Zone 2 waterways and German sea arms like the Ems, Dollard, Weser, and Elbe. This air horn is required for vessels over 20 meters in length, with a sound level of 132 dB at 1 meter and a base frequency between 130 and 350 Hz. AT 150/330 zone 2
 
IMO Requirements for Zone 2 Waterways

In Germany, Zone 2 waterways require an air horn that complies with IMO regulations. Ships over 20 meters must have an air horn that delivers the specified sound level and frequency to ensure safety and proper signaling. The AT150/330 meets these stringent standards, offering reliable performance under varying conditions.
 

Easy Installation and Customization

The air horn comes with a specially designed bracket, allowing it to be easily installed and adjusted in any direction to fit different vessel setups. Brackets are available in durable aluminum and stainless steel to suit various installation environments.

Additionally, the air connection is highly customizable, providing flexibility for both the horn and the air control unit to meet specific requirements. This makes the AT150/330 adaptable to various ship systems.
 

Certified for German Regulations

To ensure compliance with German regulations for Zone 2 waterways, the AT150/330 comes fully BSH certified. Its combination of power, ease of installation, and regulatory approval makes it the ideal choice for ships navigating these areas.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 330 Hz
  • Sound Pressure Level (1m):
    Total: 148 dB
    1/3 octave IMO limit: 138 dB
  • Air consumption: 20 – 30 I/s
  • Standard with Solenoid Valve TV 88
  • Weight: 11,5 kg
  • BSH Approval
MTX 150/130
Kockum Sonics / Vessel LOA 75m - 200m / Whistles & Tyfons

MT 150/130 Electro-Tyfon®

 
part no.

24800171

product options

MT 150/130 electrically driven piston whistle, suitable for vessels with a LOA 75m till 200m.

 

General Information

The ELECTRO–TYFON® MT 150/130 is an electrically driven piston ship’s whistle. It features minimal moving parts, a “swinging piston,” a cylinder that requires no lubrication, and an oil-free gearbox.

 

Key Features

  • Unsymmetrical Sound Distribution: The design ensures the sound is distributed unevenly for efficient signaling.
  • Adaptability: It operates effectively in all temperatures without additional measures.
  • Stability: The whistle remains unaffected by voltage and frequency fluctuations.
  • Maintenance-Free: The whistle is oil-free, non-corrosive, and requires no maintenance.
  • Easy Installation: Simplified installation process.
  • Compliance: Fully complies with International Regulations IMO 1972.

 

All-Temperature Operation

The ELECTRO–TYFON® MT 150/130 delivers high performance in both arctic and tropical climates. Its patented system, featuring a high-efficiency rectangular horn and a specially designed motor, automatically adjusts the motor speed to match the horn’s acoustic resonance, regardless of ambient temperature. This ensures the whistle remains unaffected by onboard voltage and frequency fluctuations.

 

Unsymmetrical Sound Distribution

IMO Regulations demand a high Sound Pressure Level for effective signaling, but the sound level at the vessel’s listening posts should not exceed 110 dBA. To solve this, the whistle is typically placed high above the deck. However, if the highest point is insufficient, doubling the distance between the listening post and the whistle can reduce noise by 6 dB.

 

Contact Us for More Information

If you have any questions or require Kockum Sonics ship whistle or spare parts.

Contact us.

 

 

Technical Data:

  • Sound frequency (basic): 130 Hz
  • Sound Pressure Level acc to IMO (1/3 oct band): >138 dB/1m
  • Sound Level A-weighted: 142 dBA/1m
  • Electrical protection class: IP 56
  • Colors:
    Body Galvanized nat.
    Motor Grey RAL 7030
    Horn White RAL 9003
  • Weight (approx.): 68 kg

 

COMMON SPARE PARTS AVAILABLE FROM STOCK:

 

Manufacture PN

Description

Remark

20862066 O-ring
20880002 Bearing for Crankshaft
20880003 Bearing front
20880005 Bearing rear
21750120 Horn
21750123 Horn
21765049 Packing
21768357 Gear wheel 50Hz
21768358 Motor gear wheel 50Hz
21768359 Gear wheel 60Hz
21768360 Motor gear wheel 60Hz
21768365 Base plate
21768368 Ring
21768373 Spacer
21768376 Spacer
21768399 Cap
21768404 Spacer
21768984 Outlet
21768986 Cylinder
21769057 Crank case
21769059 Cover
21769060 Fixing screw
21800321 Motor set 380-440V/50-60Hz Superseded by 24800705
24530281 Crank shaft set
24530291 Piston rod set
24530293 Vibration damper set
24530294 Clamp set
24530296 Piston complete set
24530297 Mounting details
24800705 Motor set 380-440V/50-60Hz
24800706 Motor set 660-690V/50-60Hz
32470024 Circlip

 

Send your inquiry to info@venteville.com

MTX 150/130
Kockum Sonics / Vessel LOA 75m - 200m / Whistles & Tyfons

MT 150/140 Electro-Tyfon®

 
part no.

24800569

product options

ELECTRO–TYFON® MT 150/140 is an electrically driven piston ship’s whistle. It is built up of comparatively few moving parts as the “swinging piston”, no lubricated cylinder and an oil free gearbox.

  • Electrically driven (Power source)
  • 140Hz  (Fundamental frequency)
TK80 – Contactor Unit
Kockum Sonics / Vessel LOA > 200m / Vessel LOA 75m - 200m / Whistles & Tyfons

TK80 Contactor Unit

 
part no.

24800602

product options

General Information

To ensure safety, the TK80 contactor unit includes a thermal overload relay that protects the installation from excessive current. This relay has a set point of 13A, providing reliable protection during operation. By default, the relay operates with an automatic reset feature (A), which simplifies management for users. However, operators can change the relay function to a manual reset option (H). In this case, the user must reset the overprotection using the green pushbutton, adding an extra layer of control.
 

Additional Features

Moreover, the unit supplies heating voltage to the ELECTRO-TYFON®. This heating voltage automatically switches off during signaling, optimizing energy efficiency and enhancing safety. As a result, operators can count on the system for consistent performance and protection under various conditions. Overall, these features make the contactor unit a vital component in ensuring reliable and safe operation.
 

Contact Us for More Information

If you have any questions or require the TK80 of Kockum Sonics.

Contact us.

Technical Data

  • Main voltage:  max 690V AC
  • Control voltage:  230V AC, 50/60Hz (other voltages optional)
  • Heating:  30 – 55 V AC, max 100 VA
  • Operating ambient temperature: 0…+50 °C
  • Protection class: IP54

Dimensions

  • W x H x D: 300 x 300 x 155 mm
  • Mounting holes: 4 x Ø8.5 mm
  • Distance between mounting holes: 260x260mm
  • Cable glands: 2 pcs M32 for cable Ø 19 – 31 1 pc M25 for cable Ø 11 – 20
  • Connection plinths: Cables Ø 0,52-6mm.
  • Colour: RAL 7035
  • Weight: 7.9 kg
Venteville Brands