Venteville, agent, distributor, service provider of Kockum Sonics
Venteville

Vessel LOA > 200m

Pre-COLREG 1972 Sound Practices

Before the introduction of COLREG 1972, smaller vessels often used low-pitched tones, which were typically reserved for larger ships. This practice was not as strict as required. However, modern IMO regulations ensure that very low tones are exclusively used by the largest vessels, while medium and smaller vessels have more flexibility in frequency selection. Vessel LOA > 200m

Whistle Options for Large Vessel LOA > 200m

Kockum Sonics offers specialized whistles for vessels 200 meters or longer. The ELECTRO–TYFON® MTX 150/130, an electrically driven piston whistle, features minimal moving parts and a unique design that reduces deck noise by 6–8 dB. Additionally, air-driven whistles like the MKT 150/110 and MKT 150/90 meet IMO standards for large ships, delivering powerful sound performance.

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

contact us.
MKT 150/90

Kockum Sonics

MKT 150/110 Supertyfon®

 
product options

MKT 150/110 air whistle, suitable for vessels with a LOA > 200m

 

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

 

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels over 200 meters (656 feet) should use whistles with frequencies of 130 Hz or lower. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for MKT 150/110

Mounting the MKT 150/110

Secure the MKT 150/110 whistle with four M12 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for ensuring optimal performance. To begin with, it is recommended to drain the filter approximately once a month. By doing so, you can effectively prevent blockages while also maintaining the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 110 Hz
  • Sound Pressure Level (1m):
    Total: 149 dB
    1/3 octave IMO limit: 143 dB
  • Air consumption: 60-70 I/s
  • Air supply pressure: 0,6—3 MPa (6—30 bar)
    Please state the working pressure when order.
  • Electric power:
    Thermostat heating: 24 W
    Valve: 27 W
  • Weight: 52 kg
  • For wiring diagram: see Valve Unit TV 784
MKT 150/90

Kockum Sonics

MKT 150/90 Supertyfon®

 
product options

MKT 150/90 air whistle, suitable for vessels with a LOA > 200m

 

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

 

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels over 200 meters (656 feet) should use whistles with frequencies of 130 Hz or lower. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for MKT 150/90

Mounting the MKT 150/90

Secure the MKT 150/90 whistle with four M12 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for ensuring optimal performance. To begin with, it is recommended to drain the filter approximately once a month. By doing so, you can effectively prevent blockages while also maintaining the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 90 Hz
  • Sound Pressure Level (1m):
    Total: 149 dB
    1/3 octave IMO limit: 143 dB
  • Air consumption: 60-70 I/s
  • Air supply pressure: 0,6—3 MPa (6—30 bar)
    Please state the working pressure when order.
  • Electric power:
    Thermostat heating: 24 W
    Valve: 27 W
  • Weight: 52 kg
  • For wiring diagram: see Valve Unit TV 784
MTX 150/130
 
part no.

24800287

product options

MTX 150/130 electrically driven piston whistle, suitable for vessels with a LOA >200m.

 

General Information

The ELECTRO–TYFON® MTX 150/130 ship whistle is electrically driven piston designed for large commercial vessels with LOA above 200 meters. It delivers powerful, regulation-compliant sound signaling while maintaining low noise levels at onboard listening positions. It features minimal moving parts, a “swinging piston,” a cylinder that requires no lubrication, and an oil-free gearbox.

 

Key Features

  • Unsymmetrical Sound Distribution: The design ensures the sound is distributed unevenly for efficient signaling.
  • Adaptability: It operates effectively in all temperatures without additional measures.
  • Stability: The whistle remains unaffected by voltage and frequency fluctuations.
  • Maintenance-Free: The whistle is oil-free, non-corrosive, and requires no maintenance.
  • Easy Installation: Simplified installation process.
  • Compliance: Fully complies with International Regulations IMO 1972.

 

Consistent Performance in All Climate Conditions

The MTX 150/130 ship whistle performs reliably in arctic, tropical, and high-humidity environments without additional heating or cooling systems. Thanks to its patented rectangular horn and adaptive motor control, the whistle automatically adjusts motor speed to the horn’s acoustic resonance. Therefore, it maintains consistent sound output regardless of ambient temperature, voltage, or frequency fluctuations—an advantage over many alternative electric and pneumatic ship whistles.

 

IMO-Compliant Sound Distribution and Easy Installation

To meet IMO 1972 sound signaling regulations, the MTX 150/130 features unsymmetrical sound distribution. This design delivers the required Sound Pressure Level for navigation while keeping noise at listening posts below 110 dBA. Furthermore, the electrically driven configuration allows fast and straightforward installation, even where compressed air systems are impractical. Compared to competing marine whistles, this results in quieter onboard environments and easier retrofitting.

 

Contact Us for More Information

If you have any questions or require Kockum Sonics ship whistle or spare parts.

Contact us.

Send your inquiry to info@venteville.com

 

Technical Data:

  • Sound frequency (basic): 130 Hz
  • Sound Pressure Level acc to IMO (1/3 oct band): >143 dB/1m
  • Sound Level A-weighted: 146 dBA/1m
  • Electrical protection class: IP 56
  • Colors:
    Body Galvanized nat.
    Motor Grey RAL 7030
    Horn White RAL 9003
  • Weight (approx.): 84 kg

Common Spare Parts Available From Stock:

Manufacture PNDescriptionRemark
20750100Connection box
20862066O-ring
20862066O-ring 57,6 x 2,4
20880002Bearing for Crankshaft
20880003Bearing rear
20880005Bearing front
21750123Horn
21765049Packing
21768357Gear wheel 50Hz
21768358Motor gear wheel 50Hz
21768359Gear wheel 60Hz
21768360Motor gear wheel 60Hz
21768368Flange
21768373Spacer
21768376Spacer
21768399Cap
21768404Spacer
21768473Mounting flange
21768545Crankshaft Gear Wheel 60 Hz
21768984Outlet
21768986Cylinder
21769059Cover
21769060Fixing screw
21769060Screw
21769402Cylinder
21800420Motor set 380-440V/50-60Hz
21801030Motor set 660-690V/50-60Hz
24530267Motor Gear Wheel 50 Hz
24530268Motor Gear Wheel 60 Hz
24530291Piston rod set
24530292Crank shaft set
24530292Crankshaft Set
24530293Vibration damper set
24530294Clamp set
24530296Piston set
24530297Mounting details
24800585Crank shaft set
24800703Motor set 380-440V/50-60Hz
24800704Motor set 660-690V/50-60Hz
32470024Circlip
32470028Circlip
34240705Bearing (2 in set) for motor
20611031Motor set 440V/60HzObsolete

 

TK80 – Contactor Unit

Kockum Sonics

TK80 Contactor Unit

 
part no.

24800602

product options

General Information

To ensure safety, the TK80 contactor unit includes a thermal overload relay that protects the installation from excessive current. This relay has a set point of 13A, providing reliable protection during operation. By default, the relay operates with an automatic reset feature (A), which simplifies management for users. However, operators can change the relay function to a manual reset option (H). In this case, the user must reset the overprotection using the green pushbutton, adding an extra layer of control.
 

Additional Features

Moreover, the unit supplies heating voltage to the ELECTRO-TYFON®. This heating voltage automatically switches off during signaling, optimizing energy efficiency and enhancing safety. As a result, operators can count on the system for consistent performance and protection under various conditions. Overall, these features make the contactor unit a vital component in ensuring reliable and safe operation.
 

Contact Us for More Information

If you have any questions or require the TK80 of Kockum Sonics.

Contact us.

Technical Data

  • Main voltage:  max 690V AC
  • Control voltage:  230V AC, 50/60Hz (other voltages optional)
  • Heating:  30 – 55 V AC, max 100 VA
  • Operating ambient temperature: 0…+50 °C
  • Protection class: IP54

Dimensions

  • W x H x D: 300 x 300 x 155 mm
  • Mounting holes: 4 x Ø8.5 mm
  • Distance between mounting holes: 260x260mm
  • Cable glands: 2 pcs M32 for cable Ø 19 – 31 1 pc M25 for cable Ø 11 – 20
  • Connection plinths: Cables Ø 0,52-6mm.
  • Colour: RAL 7035
  • Weight: 7.9 kg
Venteville Homepage